  • To synchronize the Master and Slave show, their show time have to be the same.
    It is therefore recommended to use an incoming timecode.  You have to set the Show Time Mode in the Show Properties to TimeCode Chase in that case, on all Ovation Computers.
  • For sample accurate sync, you must also use a video reference, and run in MassCore Mode.
  • Connect all the Ovation computers to the same TC source.  
    In ANEMAN / RAVENNA Easy Connect, connect all Ovation MassCore to the same Horus/Hapi LTC.
    For your convenience, you may also display the TimeCode Reader and set it to show your LTC source.
  • A pre-roll of up to two seconds is required before output begins from a slave Ovation.

...