Note : 
  • Switches for RAVENNA / AES67 must be in managed mode and properly configured.
  • RAVENNA/AES67 network should have its own VLAN and not mixed with other network types.
  • To use several interconnected switches, please also see the Multiple network switches considerations page.



BrandModelPortsRemarks
ArtelQuarra PTP range (StagedBox)8+2SFPPTP aware switchConfiguration Guide
Aruba2930M44+4SFPNot fully tested by Merging, but reported to work on RAVENNA
CiscoSG-300-10 / 208+2 /16 +4 (sfp or copper)
Configuration Guide
CiscoSG-350-108+2 (sfp or copper)
Configuration Guide
CiscoSG-350-10P8+2 (sfp or copper)PoE+ up to 60W (Max 3 Anubis per switch)Configuration Guide
DellPowerConnect 2808/28168 / 16 portsLegacy - discontinuedConfiguration Guide


Not recommended switches:

BrandModelRemarks
DellX1000 seriePoE
DellX1008PPoE (<15.4W)PoE not sufficient for Anubis
ZyxelGS1200-8HPPoEIGMP does not work
UbiquitiUniFi US-8-60WPoENo QoS. Need external software controller, not supported by Merging's support
TP LinkTL-SG108PEPoEPoE may not be sufficient for Anubis. QoS hardcoded.